BS 8210:2020 Facilities Maintenance Management

Fire safety is a paramount concern for any building, and having a robust fire escape plan in place is crucial for the protection of occupants and assets.

While many aspects of fire safety are well-known and widely practiced, the importance of regular fire escape inspections conducted by qualified structural engineers, in accordance with standards such as BS 8210:2020, cannot be overstated. In this blog post, we’ll delve into why these inspections are vital for ensuring compliance and safeguarding lives.

external fire escape inspection


BS 8210:2020

Facilities maintenance management: Code of Practice


BS 8210:2020, published by the British Standards Institution, provides comprehensive guidelines for the design, construction, and maintenance of escape routes in buildings, including external fire escape staircases.

This standard emphasises the importance of regular inspections to ensure these escape routes remain safe and reliable in the event of an emergency.




Why Entrust Fire Escape Inspections to Qualified Structural Engineers?

The answer lies in their expertise and understanding of structural integrity. Structural engineers possess the knowledge and skills to assess the condition of fire escape staircases thoroughly.

Structural Engineers can identify potential structural weaknesses, signs of deterioration, or damage that may compromise the effectiveness of the escape routes.



BS 8210:2020 specifies the qualifications and competence required for individuals performing fire escape inspections.

Qualified structural engineers are well-equipped to meet these criteria, ensuring that inspections are conducted to the highest standards of professionalism and accuracy.

Regular Fire Escape Inspections By Qualified Structural Engineers Offer Several Benefits …

fire escape inspections

Furthermore, fire escape inspections by structural engineers instill confidence and peace of mind among building occupants and stakeholders.

Knowing that fire escape routes are regularly inspected by qualified professionals provides reassurance that appropriate measures are in place to protect lives and property during emergencies.

fire escape inspection


In conclusion, fire escape inspections by qualified structural engineers play a pivotal role in maintaining fire safety standards and ensuring compliance with regulations such as BS 8210:2020.

Investing in these inspections is an essential aspect of responsible building management, prioritising the safety and well-being of all occupants. By staying proactive and vigilant, we can mitigate risks and create safer environments for everyone.


Do you mange the health and safety of people in and about your building(s)? So that we can understand your requirements, it’s easier to talk.

Either call us on 0118 962 9666 or simply fill in your details below and we’ll get back to you at your convenience.

Please note, for one off inspections we generally work within a 50 mile radius of Reading. For multiple sites we work nationwide.

Click here to check out other Blog Post regarding external fire escape inspections.

contact Us

Today I’m talking to Oliver Goodyear, Engineering Manager at Michael Aubrey Partnership about the main issues associated with fire escape inspections and how we helped a recent client.

What Are The Main Issues That You Encounter When Carrying Out A Fire Escape Inspection?  

One of the main issues with these types of structures is that they are rarely used and, in most instances, never tested for a mass egress scenario, as fortunately fires are rare. 

But because of this, these structures are often found neglected and left to deteriorate. 

Unfortunately, we are finding that there are an alarming number of inadequate staircase structures out there, that may struggle to provide their intended function at their hour of need. 



What Do You Normally Look For During A Fire Escape Inspection?

In general, we are looking at two items. Firstly, is the fire escape staircase structurally safe, i.e would it support the load imposed by a mass egress scenario?

We do this by checking the structural condition of each staircase component and connection. 

Most staircases are usually steel and we find deterioration due to corrosion is the most common defect. 

However often we are finding the corrosion is exacerbated by poor detailing (leaving somewhere for water to collect), the wrong type of bolt or even the wrong type/poorly applied paint. 





Secondly, if the staircase is deemed structurally safe, the other item we assess is whether the staircase itself is safe to use in terms of functionality.

We often try to align this with Building Regulations and check that the

  • surface is grippy
  • the handrails do not have large gaps which may present a fall hazard to children
  • there are no obstructions to the escape route. 

We have had instances in the past where say a satellite dish over sails the staircase and would cause a head clash or where bird waste or litter is left to congregate on the stairs. 

Often menial and easy to resolve items, that would make a massive difference if the staircase is called into use.


What Happened At This Particular Site?

This particular site was a school in Brighton.

So automatically we were thinking high salinity in the air (steel structures tend to have shorter lives in these environments, often regularly meaning maintenance and recoating). 


This particular staircase was a straightforward single flight and landing serving a first-floor landing and was noticeably rusty. 


Painted System – Regular Maintenance

The superior corrosion protection for these types of structure is usually a galvanised structure. 

This one was a painted system, which was fine but usually needs more regular maintenance and in this instance the paintwork was worn, and the steel was corroding.

The corrosion was fairly advance, and sections of the steel structure were beginning to delaminate/break apart. 





Worst Affected Area

The worst affected area was to the base of the column, where two of the columns had failed and the square tube had been completely eaten through with corrosion. 

This is a common issue with steel tubes in contact with the ground as water can become trapped inside the tube and eaten away at both the inner and outer faces, which had occurred in this instance.



The Technical Solution

The staircase needed extensive remedial works which effectively involved taking it all apart and sanding back the corrosion to clean metal and putting it back to together with new fixings, whilst applying a new primer and topcoat system. 

The corroded columns were to be cut back to an appropriate height and replaced with concrete plinth type foundations. 

The benefit of this solution is that concrete is very durable and we can get the steelwork well above ground level where prone to corrosion. 

This was fairly intensive work and would estimate around £5k, whereas a replacement staircase would be around £15-20k. 

I would anticipate around 10-20 years additional life to this structure, providing that is well maintained.

How We Helped The Client

The main way we helped the client is by allowing them to keep the current staircase in use whilst they sought remedial quotes. Normally we use a traffic light system to advise the client on the structural status.

Ordinarily two failed columns would usually be assigned a RED – i.e the structure is condemned. 

Structural Expertise

However, our structural design capabilities set us apart from other surveyors carrying out this role and we were able to assess the remaining two columns.

We found these to be adequate in supporting the structure in the short term which meant we could categorise the staircase as;

AMBER 1 – which meant the staircase needed urgent work within the next 12 months – but it could be kept in use for the short term, whilst works were organised.

The main benefit to the client was that they did not need to update their fire plan and reorganised escape routes.  Which could ultimately lead to additional protection to create new routes, suppression or even closing off an area until repairs are carried out. 

External Fire Escape Inspections

Are you a building owner?

Do you mange the health and safety of people in and about your building(s)?So that we can understand your requirements, it’s easier to talk. 

Either call us on 0118 962 9666 or simply fill in your details below and we’ll get back to you at your convenience.

Please note, for one off inspections we generally work within a 50 mile radius of Reading. For multiple sites we work nationwide.

Click here to check out other Blog Post regarding external fire escape inspections.

Contact us